5 Warning Signs Your Deaerator Needs Attention
Your boiler gets most of the attention in the boiler room, but one piece of equipment quietly plays a critical role in protecting the entire steam system: the deaerator tank.
A deaerator (DA) tank removes dissolved oxygen and other non-condensable gases from boiler feedwater before they enter the system. Why does that matter? Because oxygen and carbon dioxide are major contributors to corrosion, equipment damage, and shortened system life.
When a deaerator isn’t performing properly, the impacts may not be obvious at first. Small issues often appear as nuisance operating problems before becoming expensive repairs or unplanned downtime.

Here are five warning signs that your deaerator tank may need attention.
1. Increased Corrosion Throughout Your System
One of a deaerator’s primary jobs is removing oxygen from feedwater before it reaches the boiler.
If oxygen levels increase, corrosion can begin affecting:

- Boiler tubes
- Condensate piping
- Feedwater lines
- Economizers
- Pumps and valves
Common warning signs include:
- Rust-colored water
- Leaks developing in piping
- Premature component failures
- Thinning metal surfaces
Corrosion often develops gradually, making early detection important before more extensive damage occurs.
2. Feedwater Pump Problems
Feedwater pumps depend on a steady supply of properly conditioned water.
A deaerator operating incorrectly can create conditions that contribute to:
- Pump cavitation
- Excessive vibration
- Noise during operation
- Seal failures
- Reduced pump life
If pumps suddenly become noisy or maintenance frequency increases, the problem may not be the pump itself—it could originate upstream at the deaerator.
3. Unusual Temperature Readings
Deaerators remove dissolved gases by heating water to a specific operating temperature range.
If water temperature begins drifting lower than expected, the deaerator may not effectively remove oxygen.
Potential causes include:
- Steam control valve issues
- Steam pressure problems
- Improper venting
- Internal component wear
- Control system problems
Small temperature deviations can have larger impacts on overall boiler system performance.
4. Excessive Vent Steam or Visible Changes
A small amount of steam venting from a deaerator is normal.
However, noticeable changes in venting behavior can indicate a problem.
Watch for:
- Excessive steam discharge
- Inconsistent venting patterns
- Sudden increases in steam loss
- Unusual noises around the vent
Too much venting can waste energy and may indicate improper operation or control issues.
Too little venting may also create problems by preventing proper gas removal.
5. Fluctuating Water Levels or Control Issues
Water level instability can affect the entire boiler room operation.
Potential symptoms include:
- Rapid level swings
- Feedwater pump cycling issues
- Overflow events
- Erratic control behavior
- Low-water alarms occurring more frequently
Changes in level control can indicate:
- Faulty level controls
- Valve problems
- Internal mechanical issues
- Instrumentation concerns
Left unaddressed, these issues can create larger operating disruptions throughout the system.
Don’t Wait for a Failure
Many deaerator problems begin with small warning signs that are easy to overlook during day-to-day operation.
Ignoring them can lead to:
- Increased fuel costs
- Corrosion damage
- Unexpected shutdowns
- Reduced equipment life
- Higher maintenance expenses
Routine inspections and preventive maintenance can help identify issues before they affect the entire boiler room.

Keep Your Boiler Room Running Reliably
Your deaerator tank protects much more than feedwater—it helps protect your entire steam system investment.
Boiler Supply can evaluate your deaerator performance, inspect controls and components, and help identify potential issues before they turn into costly downtime.
Contact Boiler Supply today to schedule a boiler room evaluation or preventive maintenance inspection.